PW 200-5MAS
RECLAIM MAX. OUTPUT 60 GPM RECLAIM PUMP 5 HP SELF-PRIMING CENTRIFUGAL PUMP DRAWS 12.2 AMPS AT 208/230 VAC OR DRAWS 6.1 AMPS AT 460/480 VAC CUSTOMER TO SPECIFY VOLTAGE
DIMENSIONS 48" WIDTH X 74" TALL X 16" DEEP
NET (CRATED) WEIGHT 700 LBS
PLUMBING CONNECTIONS TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. ONE 2" LINE OUT TO THE WASH MANIFOLD ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING PUMP FUNCTION CITY WATER REQUIRED IS 60 GPM @ 40 PSIG
ELECTRICAL REQUIREMENTS ONE (1) 208/230 VAC OR 460/480 VAC 2 PHASE, 20 AMP CIRCUIT ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT
CONDUIT
ONE (1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS) ONE (1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME
TANK CONFIGURATION RECOMMENDATION TRIPLE TANK CONFIGURATION
|
|
|
|
• VFD DRIVEN CONTINUOUS DUTY MOTOR • SELF PRIMING PUMP • HIGH EFFICIENCY CYCLONIC SEPARATORS • CONTROL SIGNAL ACTIVATION • 5 MICRON WATER OUTPUT • CONTINUOUS SPARGING RECIRCULATION TECHNOLOGY FOR ODOR CONTROL • POWDER COATED FRAME • ODOR CONTROL OPTIONS |
|